Marketplace
Focus on Biometry Devices
A-SCAN PLUS
Accutome
■ The A-Scan Plus is an effective solution for measuring and calculating patients and refining surgical outcomes for cataract surgery. It has the ability to measure all patients, including those with dense cataracts and fixation difficulties. The A-Scan Plus has the best resolution and largest screen size available for precise and reproducible axial length measurements, according to Accutome. The automatic personalization of lens constants can help users achieve superior surgical outcomes and the alignment detection feature eliminates marginally aligned scans.
The software makes it possible to store up to 100 patients' measurements and uploads to a paperless office or EMR. In addition, it includes modern third-generation formulas such as the Hoffer Q, SRK/T, Holladay and Haigis, as well as new post-refractive formulas.
Accutome, Inc.
Phone: (800) 979-2020
www.accutome.com
IOLMASTER
Carl Zeiss Meditec
■ The IOLMaster has emerged as the standard of care where precise refractive outcomes are essential, as with the new multifocal and accommodative IOLs, says CZM. This easy-to-use, non-contact, all-in-one instrument measures axial length, corneal curvature, anterior chamber depth and white-to-white. IOL power calculations include third- and fourth-generation formulas as well as post-refractive surgery and phakic IOL modes. The enhanced platform offers new networking options and increased measurement speed and an integrated lens constant optimization program allows for efficient personalization to enhance outcomes. Software version 5 (Advanced Technology Software) simplifies operation through improved signal processing in axial length mode and signaling of the optimal measurement setting in keratometry.
Carl Zeiss Meditec
Phone: (800) 342-9821
www.meditec.zeiss.com
THE PACHETTE
DGH Technology, Inc.
■ The DGH Pachette is the exclusive Ocular Hypertension Treatment Study pachymeter. There are over 10,000 DGH pachymeters in use around the world. The DGH 55 Pachmate hand-held is the world's lightest ultra-high quality pachymeter, according to DGH. The Pachmate and the Pachette 3 were designed specifically for glaucoma and LASIK screening. They feature bilateral mode, running average and standard deviation. DGH's B-Scan, the Scanmate, is an economical way to perform B-Scans using a USB port on a laptop or PC.
DGH Technology, Inc.
Phone: (800) 722-3883
www.dghkoi.com
EYE CUBED ULTRASOUND SYSTEM
Ellex
■ The Eye Cubed delivers unparalleled sensitivity and the highest-quality image resolution, making it the premier device for ultrasound examination of the eye, says Ellex. Created by ophthalmic ultra-sound technology pioneers Innovative Imaging, the system features real-time imaging, advanced movie mode using the fastest sampling rate available, and internal memory for storing measurements — all of which advance and improve the diagnostic process. In addition, customized configuration of A-Scan and B-Scan modes make the device suitable for both retinal specialists and anterior segment surgeons.
Ellex
Phone: (800) 824 7444
www.ellex.com
PRAGER SHELL
ESI, Inc.
■ ESI, Inc. is the exclusive manufacturer of the Prager Shell for immersion biometry, offering nine different models. Prager Shell models are manufactured according to each A-scan manufacturer's specifications for consistent and accurate probe placement.
ESI's proprietary and patented design automatically positions the ultrasound probe perpendicular within the shell, and at the correct distance from the eye, insuring an optimum scan, says the company.
To reduce the potential for patient cross-contamination, an integrated luer connector is located on the side of the instrument for easy replacement of the used contaminated Prager Shell tubing kit. Sterile replacement kits are offered both with and without a one-way flow check-valve.
ESI, Inc.
Phone: (763) 473-2533
www.eyesurgin.com
PALMSCAN AP2000
Micro Medical Devices
■ PalmScan is a battery-operated, fully portable, ultrasonic A-Scan/pachymeter combination biometer. Its pocket size, 8.4-ounce weight and easy operation afford the freedom to treat patients anywhere or check biometry before surgery, says Micro Medical.
The AP2000 features contact and immersion biometry with automated visual axis alignment, modern IOL formulas and post-refractive correction of keratometry. PalmScan's pachymeter offers central and peripheral corneal pachymetry with IOP adjustment calculator. PalmScan's optional LRI package includes a 50MHz probe and facilitates the planning of LRIs.
This package also includes a built-in age- and pachymetry-adjusted nomogram, user-customizable nomograms and concurrent cataract and LRI vector analysis. PalmScan is also capable of performing direct measurement of femtosecond laser flaps prior to lifting of the flap. Integrated desktop software allows archiving, viewing and printing of patient reports. Bluetooth printing technology allows wireless printing of reports to office printers.
Micro Medical Devices
Phone: (866) 730-0663
www.micromedinc.com
US-4000 ECHOSCAN
Nidek, Inc.
■ The Nidek US-4000 EchoScan is a comprehensive ultrasound, which includes A/B-scan, biometry and pachymetry in a compact, lightweight device. High-resolution images are achieved through 400 lines of sampling over 60° and displayed on a 1024 × 768 XGA, touch-panel monitor. High-density scanning sectors provide ideal images for the most accurate diagnosis, says Nidek.
Using state-of-the-art algorithms, anterior chamber depth, axial length measurements and IOL power calculations are performed rapidly and accurately. Accurate measurements for dense cataracts are accomplished by pressing the "Dense Cat" and "Gate Select" switches. The pachymetry mode offers precise measurement of corneal thickness within a maximum ±5 mm.
Nidek, Inc.
Phone: (800) 223-9044
www.nidek.com
A-SCAN DB-3100
Ocuserv Instruments, Inc.
■ A-Scan DB-3100 is designed to be the most versatile unit for ultrasonic biometry and IOL power calculations, says Ocuserv. Using a computer for data entry, display and memory enables the DB-3100 to retain information on an unlimited number of IOLs, physician profiles and patient data.
The intraocular distance measurement can be performed using either contact or immersion methods in auto or manual mode. Pattern recognition algorithm in automode selects scans along the visual axis. All scans performed are stored in patient files.
IOL power calculations are performed using the HofferQ formula, which provides comparative results to SRK/T and Holladay formulas. It allows up to five IOL styles per calculation.
Ocuserv Instruments, Inc.
Phone: (718) 656-1105
www.ocuserv.com
A-2000
Ophthalmic Technologies Inc.
■ The A-2000 is a compact, portable ultrasound system that connects via USB cable to any Windows XP laptop or desktop computer. It is easy to use with built-in algorithms for difficult cases such as high myopia, dense cataracts, pseudophakic patients with PMMA acrylic and silicone IOLs, and silicone oil-filled vitreous.
The software automatically detects and selects the best scans.
Ophthalmic Technologies Inc.
Phone: (888) 517-4444
Web: www.oti-canada.com
AXIS II PR
Quantel Medical
■ With the same precision and features as the original Axis II Precision A-Scan, the Axis II PR addresses the calculation challenge of post-refractive patients by providing, six formulas for normal eyes, and an additional six formulas for post-refractive eyes. Axis II is the only A-Scan with published clinical data to prove its clinical precision is equivalent to the laser interferometer, and it works with all cataracts, says Quantel. Immersion biometry with Axis II PR can be performed on both eyes, including IOL calculation, in less than 5 minutes. The Axis II PR is also available with optional pachymetry.
Quantel Medical
Phone: (888) 660-6726
www.quantelmedical.com
E-Z AB5500+
Sonomed, Inc.
■ The E-Z AB5500+ combined A/B-scan features include color LCD, touch screen, immersion capability and six IOL formulas as well as Aramberri and Latkany post-refractive formulas. It has multiple screens for tabled, summarized and compared calculations. B-Scan image resolution is 640×480 pixels with color or gray scale image. The product has a selectable simultaneous A-Scan Vector and optional viewer software is available to download images to personal computers.
Sonomed, Inc.
Phone: (800) 227-1285
www.sonomedinc.com
AL-100 BIOMETER
Tomey
■ The Tomey AL-100 biometer is designed for fast, simple operation. Tone-assisted measurement notifies the operator when the probe is aligned and measurements recorded. The AL-100 calculates IOL power with a vast array of formulas: SRK II, SRK/T, Holladay, Haigis Standard, Haigis Optimized and Showa. Other formulas may be added as well.
Entering patient and lens data is simple and direct with the large, easy-to-read touch screen. The AL-100 stores up to 6 patients in its internal memory and up to 240 patients in the optional memory card.
It also has a built-in printer that can print either a standard waveform and IOL calculation for both eyes or a more complete printout with all of the measured and calculated data for both eyes.
Tomey
Phone: (888) 449-4045
www.tomeyusa.com