NEW PRODUCT REPORT
MALYUGIN/CIONNI CTR
1 A variation of the Cionni Capsular Tension Ring (CTR), this device comes preloaded on the EyeJet, Type 10G disposable injector. The sterilized injectors are packaged in a peel-open, contoured container. The units come the CTR already affixed with a clamp to the injector hook. Unlike the standard Type 14 CTRs, the Malyugin/ Cionni Ring has a curvature at one open end. This curvature allows the CTR to slide along the capsular bag equator, eliminating the risk of perforating the capsular fornix.
FCI Ophthalmics
www.fci-ophthalmics.com
TOMEY RC-800
2 The RC-800 AutoRefractor/Keratometer from Tomey includes features such as color touchscreen with auto-shot function and a high speed printer. For refraction, the RC-800 applies fogging automatically for each measurement. The device, to debut at the AAO annual meeting, boasts affordability as well as accuracy, according to Tomey.
Tomey USA
www.tomeyusa.com
ZIEMER LDV Z8 FEMTOSECOND LASER
The Z8 is the latest in a series of femtosecond lasers from Ziemer Ophthalmic Systems AG. The Z8 is indicated for a variety of corneal, presbyopic and cataract procedures, including corneal and arcuate incisions, precise capsulotomy and lens fragmentation. Pending approvals, the Z8 debuted at the European Society of Cataract and Refractive Surgeons meeting.
Ziemer Ophthalmic Systems AG
www.femtoldv.com
OCTOPUS 600 PERIMETER
3 The first TFT-based perimeter from Haag-Streit is a compact , stand-alone instrument that runs white-on-white perimetry and the PULSAR method for the early detection of glaucoma. The duration of the test is 2-4 minutes. It operates silently, without fans or motors. The PULSAR method is a patented flicker stimulus showing a ring pattern with different contrast levels in counter phase. The new PULSAR functionality of the Octopus 600 presents a contrast-modulated ring target that flickers at 30 Hz in counter phase. The Octopus features automated eye tracking to recognize the position of the pupil and keep the eye centered.
Haag-Streit UK
www.haag-streituk.com
VISIAN ICL PRELOADED SYSTEMS
This new preloaded system includes an enhanced optic designed to increase the useful optical zone, particularly for patients with large pupils. It also includes a new delivery system designed to reduce the operating time of the ICL procedure to five minutes or less. STARR Surgical introduced the Visian ICL Preloaded System at ESCRS.
STAAR Surgical Co.
www.staar.com
BAUSCH + LOMB MONTHLY DISPOSABLE CONTACT LENS
This B + L contact lens combines MoistureSeal technology, a silicone hydrogel material, with a new manufacturing processes. The lens is designed to be paired with Biotrue ONEday, a daily disposable contact lens released last year, and Biotrue Multi-Purpose Solution.
Valeant Pharmaceuticals International Inc.
www.bausch.com
EYEPROMISE DVS
EyePromise DVS vitamins are designed to support blood vessel health. Research suggests nutritional ingredients such as, benfotiamine, coenzyme Q-10, grapeseed extract, resveratrol, Pycnogenol, green tea leaf, and curcumin may support blood vessel health, according to parent company ZeaVision. All these ingredients are found in the DVS proprietary blend.
ZeaVision
www.eyepromise.com/dvs
PRELOADED HENDERSON CAPSULAR TENSION RING
4 The Henderson Capsular Tension Ring is now available preloaded in the EyeJet type 10C disposable injector. The injector includes a peel-open, contoured, sterilized container. Each unit comes with one of the CTRs already affixed to the hook of the injector with a clamp on the injector to prevent movement. The CTR is loaded into the injector by pushing the clamp backward. The clamp is then removed positioning the ring for insertion into the capsular bag. The Henderson Ring features eight equally spaced indentations spanning the circumference of the ring, creating a sinusoidal shape.
FCI Ophthalmic Inc.
www.fci-ophthalmics.com
LEICA MICROSYSTEMS 3D SURGICAL MICROSCOPES
The Leica M720 OH5 and M525 OH4 microscopes eliminate the need for a separate 3D cart by incorporating digital 3D technology-provided integration with TrueVision. These microscopes give surgeons control of the recording functions, without interrupting workflow with foot controls as well as hand controls. Surgeons can also use the microscopes to simultaneously stream 3D and 2D video to external monitors.
Leica Microsystems
www.leica-microsystems.com
CENTERVUE MAIA MICROPERIMETER/DRS RETINAL CAMERA FEATURES
Two devices from CenterVue have received upgrades. New features of the DRS retinal camera include an automated image mosaic function. New functionality of the MAIA microperimeter includes multiple fixation targets at selectable locations.
Haag-Streit UK
www.haagstreituk.com
RHEIN RESPOSABLE KNIVES
Resposable knives, from Rhein Medical, have glass handles that can withstand an autoclave. The knives consist of keratomes, limited-depth, and paracentesis blades. The keratomes include parallel and trapezoidal configurations. They also include a 3D feature which causes the incision to contort to provide a more torturous path for fluid egression. The knives come in packages of six.
Rhein Medical
www.rheinmedical.com OM
NPR in brief |
■ Alphaeon Corp., a wholly-owned subsidiary of Strathspey Crown Holdings LLC, has acquired worldwide licensing rights to TouchMD, an interactive patient-education software platform designed for speciality physicians. Alphaeon has also acquired an exclusive US license from Visiometrics to market the HD Analyzer. ■ Topcon Medical Systems has announced a new online training program for its CV-5000S Automated Refraction System. The program is the first in a series of interactive, online product training systems. More information is available at www.topconmedical.com/products/cv5000s.htm. ■ A pilot clinical study presented at the International Society of Presbyopia demonstrated the ability of FluidVision, (PowerVision, Inc., Belmont, CA), a foldable IOL, to restore accommodation. Principal investigator, Dr. Frik J. Potgieter presented the results. ■ Oculus has launched a new company Web site designed to showcase the company’s products, news, and information on upcoming events in an easy-to-use format. ■ Allegro Ophthalmics has received FDA approval for its investigational New Drug Application to commence two phase 2 clinical studies of integrin peptide therapy ALG-1001 for patients with wet AMD and symptomatic vitreomacular traction. ■ Haag-Streit USA will now offer Sony Electronics’ high-definition, medical-grade 3D video camera, video recorder, and displays with its line of surgical microscopes. The technology provides the ability to share a procedure in 3D in both real time and for playback. |
---|