Marketplace
Focus on Pachymetry Devices
PACHPEN
Accutome
■ The PachPen's ergonomic design makes taking measurements quick and easy. The unit has the ability to take nine readings and average them. In addition, the IOP correction calculator converts entered IOP measurements from a tonometer in seconds. Accutome says its Digital Signal Analysis actually examines waveforms and eliminates marginally aligned measurements.
Accutome
Phone: (800) 979-2020
www.accutome.com
VISANTE
Carl Zeiss Meditec
■ The Visante OCT system provides clear, highly detailed anterior segment images — including the angle — without the need for ocular anesthesia or a time-consuming water bath. Versatile in application, Visante OCT high-resolution corneal and anterior segment images, combined with analytical tools, support the evaluation of narrow-angle and ocular health.
Additionally, Visante OCT can image, measure and document post-LASIK flap and residual stromal bed thickness without touching the eye. Accurate and repeatable pachymetry map and pachymetry difference map results support refractive and glaucoma care. Optional modules enable AC-angle quantification as well as preoperative phakic IOL simulation.
Carl Zeiss Meditec
Phone: (800) 342-9821
www.meditec.zeiss.com
PACHMATE DGH55
DGH Technology
■ The DGH Pachette is the exclusive Ocular Hypertension Treatment Study (OHTS) pachymeter. There are over 10,000 DGH pachymeters in use around the world. The DGH 55 Pachmate handheld is one the world's lightest pachymeters. The Pachette 3 has all the features of the very best pachymeters, but at a lower economical price, says DGH. The Pachmate and the Pachette 3 were designed specifically for glaucoma and LASIK screening.
DGH Technology, Inc.
Phone: (800) 722-3883
www.pachymeter.com
CC-7000 AND THE SP-9000
Konan Medical, Inc.
■ Both Konan's CC-7000 and the SP-9000 have a built-in pachymeter. The device uses an electro-optical method to measure the thickness of the cornea. The CC-7000 measures the cornea thickness at the same time it photographs the endothelium. The SP-9000 model has a separate mode for increased accuracy. Pachymetry measurements are possible in five different quadrants on the cornea, which can be displayed on the readout.
Konan Medical, Inc.
Phone: (800) 941-2663
www.konan.com/hp2001/english/
PALMSCAN P2000
Micro Medical Devices, Inc.
■ The PalmScan P2000 is a true surgical pachymeter with patient database capabilities that allow quick access to patient pachymetry results. It has a 17-location corneal-mapping capability that becomes highly useful for capturing corneal thickness at non-central corneal locations. The P2000 device offers the option of a 50 MHz pachymeter probe that makes corneal measurements at the limbus easy to perform. This option is highly recommended to customers who are interested in the exclusive LRI-Nomogram features of the PalmScan.
Weighing 8 ounces and operating on dual rechargeable batteries, the PalmScan easily fits into a pocket. With the highest sampling frequency of any competing product, PalmScan immersion capable A-scan and pachymeter devices deliver the highest level of accuracy available on the market, says the company.
Micro Medical Devices, Inc.
Phone: (818) 874-0000
www.micromedinc.com
POCKET II PACHYMETER
Quantel Medical
■ The versatile and easy-to-use Pocket II pachymeter is programmable for refractive surgery or glaucoma screening. With this portable precision pachymeter powered by 4 AA batteries or AC power, users can easily move between exam rooms or satellite offices, says Quantel. A direct connection to a computer via the Visuscan software allows data processing of examinations. With a measurement range of 200 to 999 μm and accuracy of ±5 μm, the Pocket II is designed to measure corneal thickness in a wide variety of clinical and surgical applications. The Quantel Medical Pocket II pachymeter combines ease of use with one-touch accuracy, precision and reliability, says Quantel.
Quantel Medical
Phone: (888) 660-6726
www.quantelmedical.com
OCULAR RESPONSE ANALYZER
Reichert
■ The Reichert Ocular Response Analyzer not only enables the measurement of central-corneal thickness, it also presents a direct measure of corneal biomechanical properties. This new measurement, called corneal hysteresis, is an indicator of the overall integrity of the cornea, providing more complete information than thickness alone.
The system is able to present IOPcc, a new measure of IOP that correlates with Goldmann, but is less affected by corneal properties, such as elasticity, resistance and thickness.
Reichert
Phone: (716) 686-4500
www.reichertoi.com
PACSCAN
Sonomed
■ The Sonomed PacScan is a portable, digital pachymeter with intuitive touch-screen operation and automatic scan capture. The 20 MHz transducer provides excellent accuracy and measurements as thin as 125 μm, says Sonomed. On-board diagnostic system calibration and probe sensitivity tests are performed automatically to ensure accurate and repeatable readings. PacScan is available as a stand-alone pachymeter or combined A-scan/pachymeter.
Sonomed, Inc.
Phone: (800) 227-1285
www.sonomedinc.com
SP-100 HANDY PACHYMETER
Tomey
■ The Tomey SP-100 Handy Pachymeter weighs only 19 ounces and provides highly accurate measurements of central corneal thickness. The SP-100 offers IOP calculations, built-in printer and an RS-232C communication port for quick recording and easy data output to office computers. The built-in rechargeable battery enables wireless operation. The easy-to-read print out includes patient ID, name and measured date.
Tomey
Phone: (888) 449-4045
www.tomeyusa.com
EAGLE EYE 3000
Vision Medical Instruments
■ Vision Medical Instruments' Eagle Eye 3000 is a user-friendly, precision pachymeter. Its 0.25 μm precision and ±1 μm repeatability makes it unnecessary to perform any additional "filtering" or "averaging." It has a built-in printer/computer interface and is the only pachymeter compatible with OfficeMate Practice Management Software. Vision says the Eagle Eye 3000 is the only pachymeter that selfcalibrates. This feature provides accurate performance for the life of the unit. Vision Medical offers a 5-year warranty.
Vision Medical Instruments
Phone: (440) 338-5981
www.visionmedicalusa.com
Other Products
OPHTHALMIC IMAGING SYSTEMS
Software, Symphony and Symphony Encore
■ OIS recently introduced OIS WinStation XP Version 10.5 Software, Symphony and Symphony Encore. OIS WinStation XP Version 10.5 Software's increased capabilities include: AutoMontage OnTheFly, enabling photographers to capture images direct to OIS's AutoMontage module; AutoEnhance, a method of automatically optimizing every image individually, both during capture and in review; and AutoStabilizer, allowing precise alignment of an entire series of images for easier clinical evaluation.
OIS Symphony, OIS's Ophthalmic PACS solution, provides integration, storage and customized access to data and images from a variety of diagnostic devices. Symphony allows comparisons of OCT and fundus images with visual field data. This product is ideal for tracking the progression of various disease states, says the company.
OIS Symphony Encore facilitates Web accessibility for healthcare providers to review WinStation and/or Symphony data and images from any Internet access point, without the need of an expensive server at the clinic.
Ophthalmic Imaging Systems
Phone: (800) 338-8436
www.oisi.com
EX-PRESS INSERTER
Optonol
■ Optonol's Ex-PRESS Delivery System (EDS) is an instrument for simple insertion of the Ex-PRESS mini glaucoma shunt. The EDS eliminates the need for manual removal of the Ex-PRESS from the introducer after insertion. It features a precise mechanism of action allowing for reproducible implantation technique and an easy-release tip allowing for gentle device placement. The single-use injector takes only seconds to load the shunt, simplifying the procedure.
Optonol
Phone: (877) 707-3937
www.optonol.com
TORIC REFERENCE MARKER
ASICO LLC
■ ASICO's Nuits/Lane Preop Toric Reference Marker, designed to be used with ASICO's Intraop Toric Axis Marker, delivers precise alignment, according to the company. The marking pattern is located on both sides for marking the left and right eye temporally. The marker's specially designed bubble level aids in accurately marking the 3, 6 and 9 o'clock positions.
Other features include more cutouts on the marker surface and laser lines on the non-marking surface for increased visibility and visualization, marking points that contour to the shape of the eye, and a light-weight all-titanium body.
ASICO LLC
Phone: (800) 628-2879
www.asico.com
STERILIZATION TRAYS
Bausch & Lomb Storz Instruments
■ Bausch & Lomb Storz Instruments introduces two double-layer instrument sterilization trays to its line of surgical instruments. The E7411 Double Layer Microsurgical Instrument Tray is 6×10×1.9 inches in size and holds 20 to 30 instruments. This double-layer sterilizable plastic tray has silicone matting on both layers for supporting and protecting instruments.
The E7421 Retina Sterilization Tray holds five retina handles, five retina tips and up to 15 additional instruments. This double-layer sterilization tray securely holds retinal handles and tips in bottom layer. In addition, the tray contains place-holders for the Retinal Tip Identification System.
Bausch & Lomb Storz Instruments
Phone: (800) 338-2020
www.storz.com
AUTOMATIC CHART PROJECTOR
Marco
■ Marco has introduced their newest Automatic Chart Projector, the CP-770. Integrating the same advanced features as the previous model 690A, the CP-770 incorporates a much smaller, lighter and more modern design.
New features include an LED illumination system, which eliminates the need for bulbs and provides a more consistent, even illumination image. Also featured is a smaller, more streamlined remote control and a redesigned table and wall mounts.
Marco
Phone: (800) 874-5274
www.marco.com
INTRAOCULAR RULER
Rhein Medical, Inc.
■ The Henry 24g millimeter ruler, developed in coordination with Michael M. Henry, M.D., slides easily through a 1 mm paracentesis and is configured like a spatula for easy and effective sweeping of the iris and manipulation of a nucleus. The shaft is strong enough to be used as a rotator, as well as for manually dissecting a nucleus. The anterior surface contains 10 dimples spaced exactly 1 mm apart. The fifth dimple is larger than the others for quick and easy reference to a 5 mm distance, making it ideal for measuring the size of a capsulorrhexis. Because the new accommodative lenses are capsulorrhexis-size dependent, the Henry ruler solves the guesswork in sizing the rhexis, says Rhein.
Rhein Medical
Phone: (813) 885-5050
www.rheinmedical.com
MAGNIFYING LAMPS
Daylight Company LLC
■ Daylight's circular Ultra Slim and the rectangular Deluxe Magnifying Lamps are designed to create optimum lighting conditions for individual needs The lamps incorporate a host of unique features including new head joints to smoothly direct the light precisely where it is needed, without adjusting the wing-nut and high quality metal arms for optimal flexibility and durability.
Both lamps naturally feature powerful Daylight low-heat light to ensure users can focus longer, increase productivity and maintain high quality standards.
Daylight Company LLC
Phone: (866) 329-5444
www.daylightcompany.com